Vue de la page 27
Any-Weigh™ Series Bench Scales
5-6
1. First byte of first word on the input data is the
new valued wanted.
2. Upper byte of first word should be 0 and is not
used.
3. Lower byte of second word is the parameter num-
ber. Averages is parameter #5.
4. Upper byte of second word is set to “1” to indi-
cate write.
This causes the unit to write the value in the first byte
of the first word to the Averages parameter. During
the execution of the command, the output polled data
reflects the input polled data.
Vue de la page 27