Any-Weigh™ Series Bench Scales
6-2
THE BUTTON
®
Enables one-touch electronic calibration of the scale
when it is empty. Access to THE BUTTON and asso
-
ciated Module LED is located at the bottom of the
scale through an access port. (See Fig. 6-1)
FIG. 6-1 THE BUTTON LOCATION/BOTTOM
VIEW
Step 1. Make sure that there is nothing in the ves-
sel or on the scale.
Step 2. Check to be sure that the Module LED is
green.
•If the Module LED is NOT green do
not complete the calibration.
•If the Module LED is Green go on to
Step 3.
Step 3. Press and hold the Red Button until the
Module LED goes off. Keeping holding
THE BUTTON down until the Module
LED comes back on.
Step 4. When the Module Status LED comes back
on. Release the RED BUTTON. The
weigh module system is calibrated.
Step 5. If the LED does not come back on contact
Hardy Technical Support for assistance.
C2
®
Calibration
from
RS NetWorx
®
Step 1. On the PC Desktop, open RS NetWorx
®
Step 2. Browse the Network.
Connector
The Button
Dip Switch
Module LED